![]() ![]() To lock, turn the "key” until it is vertical. Push connecting rod of top pump down into the slot of the pump below until it clicks into place. Avoid external mechanical influence! Locking Devices Together Place one device on top of the other. Special care is required here if a patient is already connected. Decimal pointĪlarm indicator Transport A maximum of three devices may be connected together. Start/Stop Infusion Special Functions / Function key First press F to access the special functions of the pump (= Select / Enter key). In the event of power failure, the pump automatically switches to battery power. Mains Connection Connection for the power supply. Multi-Function Connector (MFC) Connection for staff call, ambulance (12 V) and interface. Locking Lever To move the drive unit manually, push the locking lever up until it clicks. Taking care to observe waste disposal regulations (see also page 21). Remove screw (1), press in the green tab (2) and slide compartment door down. Instructions for Use and Syringe Table Slide-out short instructions for Use and a syringe table are attached underneath the pump.īattery Compartment Disconnect the pump from the patient while changing the battery. Syringe Holder Locks the syringe in place. Operation To access functions, first press the F buttonĭisplay Shows all important information at a glance: rate, syringe type, power source, infusing symbol and alarm symbols (see "Alarms” on page 11). Handle Always use the handle when carrying. For further details please refer to the Instructions for Use. The medical specialist must decide on suitability for application on the basis of the warranted properties and the technical data. IEC/EN 6 a transportbale infusion syringe pump for administrating fluids in nutritional therapy and infusion technique as well as for home care applications. The Perfusor® compact S is according to IEC/EN 60601-1 resp. HF surgical equipment, nuclear spin tomography units, mobile telephones etc.) maintain the recommended protective distances for these devices. If the equipment is operated in the vicinity of other equipment which may cause high levels of interference (e.g. ➤ The EMC-limits (electro-magnetic compati bility) according to IEC/EN 6 and IEC/EN 6 are maintained. Safety Standards Perfusor® compact S satisfies all safety standards for medical electrical devices in compliance with IEC/EN 60601-1 and IEC/EN 6. The international standard IEC/EN 6 has to be taken into account. The user/operator is responsible for the system configuration if additional equipment is connected. IEC/EN 60950 for data-processing equipment). ➤ Connected electrical equipment must comply with the relevant IEC/EN-pecifications (e.g. incompatible disposables may influence the technical specifications. ➤ Use only compatible combinations of equipment, accessories, working parts and disposables. ![]() ➤ Refer to respective manufacturer’s information for possible incompatibilities of equipment resp. ➤ Where several infusion lines are connected on one single vascular access the possibility of their exerting a mutual influence vice-versa cannot be excluded. ![]() as caused by change of level) can affect the accuracy of the device. Other components ➤ Variations in pressure (e.g. ➤ If staff call is used we recommend to check the equipment once after connecting the pump. ➤ Do not use the device when service indicator is displayed permanently. Start infusion only if values are corresponding. ➤ Compare displayed value with entered value. ➤ Possible explosion hazard if used in presence of flammable anaesthetics. Observe national specifications and deviations. ➤ Installation in medically used rooms must comply with the appropriate regulations (e.g. ➤ Recommended change of disposables after 24 h (consider national hygiene regulations). Braun perfusor compact user manual free#➤ Position the infusion line free of kinks. ➤ Select syringe/catheter suitable for use with the intended medical application. Interrupt the connection during syringe changes to prevent incorrect dose delivery. ➤ Connect to patient only after switching on the device. ![]() Also check the device for possible damage. ➤ Prior to use check audible and visual alarms during self test. Operation ➤ Ensure the unit is properly positioned and secured. Application only under regularly supervision by specially trained staff. Patient Safety Attention: Consult accompanying documents ! ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |